Marine Guidance Note

MGN 407

Testing fire protection for composite, wood constructions

In force
In force
Version
As first issued
Published
28 March 2013
Applies to
Merchant ships · Fishing vessels · Large commercial yachts · Small commercial vessels
Topics
Safety equipment · Survey and certification

xplor’s summary, not the official text

This guidance sets out how to demonstrate fire protection for composite (GRP) and wooden ship constructions, which are not steel or equivalent. It describes research on plywood, monolithic GRP, cored GRP (PVC and balsa) and the worst-case constructions to test, which can then be extrapolated to other variants. Tests use an indicative-size furnace to ISO 834-1, with compliance judged on exposed and unexposed face temperatures against HDT for composites or 140°C/180°C limits for plywood. It is addressed to owners, operators, shipbuilders, designers and surveyors, and is aimed particularly at yacht and small ship building. It is undated beyond its March 2013 publication.

Written by xplor from the notice's text on 17 November 2026. It is a summary, not the notice: rely on the official text.

Sections of the notice

  1. 1. Introduction
  2. 2. Summary of Fire Test Results
  3. 3. Procedures for Fire Testing
  4. Annex 1: Research Programme

The notice's own headings. The text of each is in the official notice on GOV.UK.