This guidance sets out how to demonstrate fire protection for composite (GRP) and wooden ship constructions, which are not steel or equivalent. It describes research on plywood, monolithic GRP, cored GRP (PVC and balsa) and the worst-case constructions to test, which can then be extrapolated to other variants. Tests use an indicative-size furnace to ISO 834-1, with compliance judged on exposed and unexposed face temperatures against HDT for composites or 140°C/180°C limits for plywood. It is addressed to owners, operators, shipbuilders, designers and surveyors, and is aimed particularly at yacht and small ship building. It is undated beyond its March 2013 publication.
Written by xplor from the notice's text on 17 November 2026. It is a summary, not the notice: rely on the official text.
Sections of the notice
- 1. Introduction
- 2. Summary of Fire Test Results
- 3. Procedures for Fire Testing
- Annex 1: Research Programme