Marine Guidance Note

MGN 651

Bilge alarms on cargo ships 24m or more in length and under 500GT

In force
In force
Version
As first issued
Published
28 July 2023
Applies to
Merchant ships · Small commercial vessels
Topics
Safety equipment

xplor’s summary, not the official text

This Marine Guidance Note explains the legal requirement under the Merchant Shipping (Cargo Ship) (Bilge Alarm) Regulations 2021 for cargo ships of 24 metres or more in length and under 500GT to fit bilge water level detectors and alarms in engine rooms and other spaces likely to accumulate bilge water. Alarms must sound audibly at the control position, be audible in accommodation spaces if not silenced within 30 seconds when the control position is unmanned, and operate when main power is inactive. The rules apply to new ships from entry into force and to existing ships within one year, on international and domestic voyages. Exemptions may be granted case by case. Risk assessment is advised where crew sleep aboard.

Written by xplor from the notice's text on 17 November 2026. It is a summary, not the notice: rely on the official text.

For yacht crew

Crew on cargo-type vessels of this size should know the bilge alarm procedures, as the notice advises risk assessment where crew sleep on board.

Sections of the notice

  1. Summary
  2. 1. Introduction
  3. 2. Requirement for Bilge Alarms
  4. 3. Bilge Water Level Detector and Alarm Functions and Capabilities
  5. 4. Exemptions
  6. 5. Increased Risks Where Crew Sleep Aboard Ships
  7. More information

The notice's own headings. The text of each is in the official notice on GOV.UK.